The full register
All entries
Every entry on the site, in register order — the homepage carries an edit; this page carries the roster.
SECTION 01 — THE FIELDtwo weeks on a wall, or eight hours on a pump.
| No. | Entry | In brief |
|---|---|---|
| E-01 | The limit decides what 'clean' means | A result below the detection limit is not zero — it is 'not seen by this method for this long'. Change the sampler or the duration and the same air produces a different sentence. |
| E-02 | The Diffusive Badge | No pump, no power: molecules arrive by diffusion at a rate the geometry fixes. Left for two weeks, it reports an average. |
| E-03 | The Pumped Tube | A known flow for a known time through a sorbent bed. Precise, short, and it needs power. |
| E-04 | Blanks | A sampler that went everywhere and sampled nothing. Without it there is no baseline. |
| E-05 | Duplicate and spike | Two checks that tell you whether the method worked on this occasion. |
| E-06 | Concentration is not exposure | One is a property of the air; the other requires knowing who was there and for how long. |
SECTION 02 — THE CHAMBERemission measured in a sealed box.
| No. | Entry | In brief |
|---|---|---|
| E-07 | Emission in a sealed box | A specimen in a chamber with controlled temperature, humidity and air exchange, sampled at intervals to give a rate rather than a level. |
| E-08 | Area-specific rate | Reported per square metre per hour, so results transfer to a room of any size. |
| E-09 | Loading and air change | The two numbers that decide what a chamber result means in a real building. |
| E-10 | The Decay Curve | Emission falls with time. Which day you sample decides the number. |
| E-11 | Sink Effects | Surfaces that absorb and release later, blurring the measurement. |
SECTION 03 — THE BENCHturning a tube into a number.
| No. | Entry | In brief |
|---|---|---|
| E-12 | From tube to number | Thermal desorption, separation, detection, integration. Four steps, each with its own way of being wrong. |
| E-13 | The Calibration Curve | Known amounts measured first, so an unknown has something to be compared against. |
| E-14 | Retention time | When a compound comes off the column — an identification, but a weak one alone. |
| E-15 | Integration | Where the operator decides a peak starts and stops. |
| E-16 | Recovery | How much of what went in came back out, and the correction applied. |
SECTION 04 — THE DOSSIERthe paper chain a substance moves through.
| No. | Entry | In brief |
|---|---|---|
| E-17 | The Paper Chain | Registration, evaluation and authorisation: the sequence a substance moves through before anything may be said about it in commerce. |
| E-18 | The Registration Dossier | What has to be submitted, and by whom, before a substance is placed on the market. |
| E-19 | Read-across | Arguing from one substance to a similar one, and the scrutiny that attracts. |
| E-20 | The Tonnage Band | How much is made decides how much has to be known about it. |
| E-21 | Data Gaps | What the record does not contain, and how that is recorded. |